Category
|
Items
|
Specification
|
Remarks
|
Power
|
Input voltage rating
|
100-240VAC
|
|
Input current rating
|
1 .3A max.
|
At full installation
|
Input frequency
|
50/60 Hz
|
|
AC adapter output voltage
|
+15V/4.0A
|
|
Voltage of inside Power switch
|
-27.3V/+5.0V
|
|
DC Switch
|
Located inside cabinet
|
Power failure back up
|
1 HPFB6: 1 hour
2 HPFB6: 2 hours See page 15
|
The amount of time depends on hardware configuration. One hour in HPFB6 means 6 CO+16DP with GVPH based on HPFB6 is fully charged.
|
Grounding
|
Customer supplied Grounding wire.
|
Ground wire must connect the earth ground through the FG terminal on the GMAU for safety purposes and to protect noise.
|
AC Plug
|
2-pin (American)
|
Ground wire must connect the earth ground through the FG terminal on the GMAU for safety purposes and to protect noise.
|
Environment
|
Operating Temperature
|
0 - 40 C
|
|
Operating humidity
|
20 - 80%
|
Storage temperature
|
-20 - 60 C
|
Safety System
|
Maximum ports
|
40
|
16: DP phones
|
6: Analog trunk
|
8: IP channel
|
4: Voicemail
|
2: Analog devices
|
4: Serial ports
|
Regulation
|
Safety
|
UL60950-1
|
USA
|
EMC
|
FCC part15 class-A
|
Network Performance
|
FCC part68
|
FCC/ACTA Registration Numbers
|
ACTA/FCC Part 68 Registration for Key System Code (KD): CJ6KD03BDTCHS402
|
ACTA/FCC Part 68 Registration for Multifunction Code (MF): CJ6MF03BDTCHS402
|
ACTA/FCC Part 68 Registration for Multifunction Code (PF): CJ6PF03BDTCHS402
|