CIX670 Power Considerations

Top  Previous  Next

Most Visited: Toshiba's All New IP5000 Series Phones | CIX40i: Big Features for Small Businesses and Branch Offices | Toshiba eManager | Toshiba CIX Business Phone Systems Product Line

The power supply in each CIX670 Base and Expansion Cabinet furnishes power to all of the stations and some of the interface peripherals (see Table 30). The primary AC power can be 120VAC, 208VAC or 240VAC. Systems containing six or seven cabinets require 208VAC or 240VAC. See page 17 for CIX40 requirements.

Table 30        CIX670 Electrical Characteristics

CIX670 Primary AC Power Voltage

Input AC

AC Frequency

Watts per cabinet (continuous) Watts for five cabinet system

115±10VAC or 208±20VAC or 240±20VAC

50/60 Hz, Single-phase (48~62Hz)

180
900

CIX670 Primary Power Current Consumption (Rating in Amperes)

Number of Cabinets:        120VAC        208VAC        240VAC

1        3.2 amps        2.2 amps        2.0 amps

2        6.4 amps        4.4 amps        4.0 amps

3        9.6 amps        6.6 amps        6.0 amps

4        12.8 amps        8.8 amps        8.0 amps

5        16.0 amps        11.0 amps        10.0 amps

6        N/A        13.2 amps        12.0 amps

7        N/A        15.4 amps        14.0 amps

Power Supply Unit (BPSU672)

DC voltage output specification

-24VDC (-26.3~-27.8VDC, 6.0 DC amps) +5VDC (+4.5~5.5VDC, 4.0 DC amps) -5VDC (-4.5~-5.5VDC, 0.8 DC amps)

 

 