Toshiba CIX40 Reserve Power

Top  Previous  Next

Most Visited: Toshiba's All New IP5000 Series Phones | CIX40i: Big Features for Small Businesses and Branch Offices | Toshiba eManager | Toshiba CIX Business Phone Systems Product Line

One or two HPFB-6 optional units can be added to the CIX40 to provide reserve power. The amount of reserve power time depends on the hardware (see Table 5). The table below is an

estimate of battery backup time based on the premise that the HPFB-6 unit(s) are fully changed at the time of AC power failure. This estimated backup time is based on normal call traffic, the time estimates will be reduced by as much as half with extreme heavy traffic volumes.

Table 5        CIX40 Reserve Power Duration Estimates

Hardware

1 HPFB-6

2 HPFB-6

3CO/8DKT/DP - No GVPH

1 hr. 40 min.

3 hr. 20 min.

3CO/8DKT/DP - with GVPH

1 hr. 30 min

3 hr.

6CO/16DKT/DP - No GVPH

1 hr. 5 min.

2 hr. 10 min.

6CO/16DKT/DP - with GVPH

1 hr.

2 hr.

11CO/8DKT/DP - No GVPH

1 hr. 20 min.

2 hr. 40 min.

11CO/8DKT/DP - with GVPH

1 hr. 10 min.

2 hr. 20 min.

11CO/16DKT/DP - No GVPH

1 hr.

2 hr.

11CO/16DKT/DP - with GVPH

55 min.

1 hr. 50 min.

 

Note The CIX40 should be plugged into AC power and the DC power switch should be turned on when installing the HPFB-6. The HPFB-6 will not start to operate if AC power is not available during the initial installation.

 


























KTS CUSTOMER USER GROUP RESOURCES | TOSHIBA CIX PHONE SYSTEMS
Sponsors Web Site
| http://www.ip-office-telephone-systems.com
Telephone Number
| (888) 4-TOSHIBA
Telephone Equipment Service Area By California County:
Los Angeles, Orange, Riverside, San Bernardino, San Diego
Site Managed By
| ABCI Web Marketing